All our sensors have been carefully selected to offer high performance at a low cost.
Thermocouple type T, exposed tip, PTFE insulated, 1 m
Type T thermocouples are a good choice for applications that require higher accuracy than Type K, but they have a narrower temperature measurement range.
PTFE insulation offers resistance to chemicals, oils and fluids, although it has a lower maximum temperature than fiberglass insulated probes.
This probe has an exposed welded tip, which offers very fast response, and are ideal for gas measurements. However, because the alloy tip is unprotected, it should not be used in corrosive or oxidizing liquids.
SE046 specifications
Type T class 1 temperature range
–75°C to +260°C
Type T class 1 accuracy
–40°C to +125°C: ±0.5°C, +125°C to +260°C: ±0.4%
Tip construction
Exposed junction / welded tip
Connector
Miniature thermocouple connector
Cable material
PTFE
Length
1 m (about 3 ft)
Cookie Policy
Essential
Analytical
Marketing
Privacy Policy
Cookie Policy
Essential
Essential cookies are strictly necessary to guarantee the proper functioning of the website.
Analytical
With this you allow us to collect anonymous data about the use of the website with third party cookies, such as the number of clicks and the behavior of visitors on the website. In addition, we can also perform marketing-related actions via this option.
By activating this cookie, you help us to further improve your experience.
Marketing
With this you allow us to collect marketing-related data via third party cookies.
By activating this cookie, you help us to further improve your experience
Privacy Policy
We use functional and analytical cookies to make our website better.Would you like to know more about our cookies? Click on "Cookie settings".