Signal Generators RadiGen® Series

The range of RadiGen EMC/RF signal generator plug-in cards are intended to be used in the RadiCentre (Pro) modular EMC test systems and are available in two models. The RGN2400A covers a frequency range from 9 kHz to 400 MHz and is mainly intended for conducted immunity test applications, like IEC61000-4-6, Mil.Std.461 CS-114 (BCI) or Automotive ISO11452-4 (BCI). The model RGN2006B covers a frequency range from 4 kHz to 6 GHz and can additionally be used for radiated immunity test applications, like IEC61000-4-3. The generator provides carrier signals from -70 dBm to +13 dBm with a frequency accuracy of +/- 1 ppm and supports different modulation types, like AM, FM and (Gated), Pulse modulation. The internal 10 MHz reference can be used as external reference source for other instrumentation.

 

Price on Request

Product specifications

SKU RAD-RGN2006A
Manufacturer Raditeq

Documentation

Please use the icons below to download any files related to this item. We aim to have the datasheet and/or catalog available.

Description

RadiGen® Signal Generators

An important part of an EMC immunity testing system is the RF signal generator, which provides the RF signal at a certain frequency with different types of modulation. This RF signal must be generated fast, accurate and without unwanted glitches or overshoot. The RadiGen® range of EMC / RF signal generators is the perfect solution for EMC applications.

Flexible

The RadiGen® plug-in card, model RGN2400A has a frequency range of 9 kHz to 400 MHz and is optimized for conducted immunity systems. The RadiGen® model RGN2006A has an additional SMA output that covers a frequency range from 9 kHz to 6 GHz, so it can also be used for radiated immunity tests such as the IEC61000-4-3 / -6, MilStd. 461 and ISO11451-2 / -4.

Accurate, fast and pure

The RadiGen® has a frequency error of ± 10 ppm and the RF carrier signal is applied to the output in less than 1 ms, with no unwanted interference at the output. All these figures and facts make it the perfect signal generator for EMC immunity testing.

 

 

CW, AM, FM and Pulse modulation

The RadiGen® generators have an internal modulator for AM and FM modulation from 1 Hz to 100 kHz. For pulse modulation, the pulse modulation on/off times can be independently set between 200 ns and 100 s with a resolution of 100 ns, allowing for any pulse pattern to be created (including gated pulse) as required by automotive standards, such as Ford RI-114 Radar Pulse testing.

10 MHz reference input/output

The RadiGen® has an internal reference clock of 10 MHz which is available as a BNC output connector for frequency synchronization of other T&M devices. In addition, it has an external reference input for a connection to an external reference clock.